What happened?
The printer is showing the message "Check the print head thermistor wiring for possible damage."
Error name: Hotend mintemp error
Error code: #26208 (MK4S) #13208 (MK4) #27208 (MK3.9S) #21208 (MK3.9)
This error is shown when the printer's nozzle temperature drops below 5 ºC at any point. If this happens during a print, the print will be stopped.
How to fix it?
Extruder inspection
This error is usually caused by the hotend thermistor.
Access the LoveBoard. Check if the thermistor is connected correctly and if there is no damage along the cable length.
If you have a multimeter, it is possible to check the resistance of the cables to verify if they are damaged. For that, use our Multimeter usage guide.
![]() | ![]() |
xBuddy board inspection
Make sure that the Loveboard main cable is correctly connected to the xBuddy board.