This error appears when the printer detects a mismatch between the expected and measured hotend temperature. It means the thermistor may not be correctly reading the actual temperature, which can be due to poor contact, incorrect mounting, or damage. The message shown is: Measured temperature is not matching expected value. Check the thermistor is in contact with hotend. In case of damage, replace it.
Error name: Hotend temp discrepancy
Error code: #31818 (CORE One) #35818 (CORE One L) #17818 (XL) #26818 (MK4S) #13818 (MK4) #27818 (MK3.9S) #21818 (MK3.9) #28818 (MK3.5S) #23818 (MK3.5) #12818 (MINI)
This issue usually comes from a loose or damaged thermistor connection to the hotend.
Nextruder hotend. Picture taken on Original Prusa MK4, shows the heaterblock on CORE One, CORE One L, XL, MK4/S, MK3.9/S.
![]() | ![]() |
| Original Prusa MINI/+ | Original Prusa MK3.5/S |
If needed, consult the hotend replacement guide as further reference on how to access the hotend.
If the problem continues even after verifying the thermistor, there could be a fault in the electronics or the temperature control loop. Contact our Support for further assistance.