What happened?
The Original Prusa XL is equipped with a loadcell, to detect that the nozzle is close enough to the steel sheet for printing, and to avoid damage that would be caused by the nozzle digging into the steel sheet.
The loadcell measures the amount of force that the nozzle applies to the steel sheet. In case the measured value is abnormally high, or undefined, the printer will show the message "Loadcell measured an infinite or undefined load value."
Error name: Loadcell measure failed
Error code: #17526
How to fix it?
A visual inspection
- the filament is unloaded from the extruder
- the printer is turned OFF and unplugged from electricity
- the hotend and the heatbed are cooled down to ambient temperature

Open the dwarf-cover-door to access the Dwarf board. The loadcell connector is on the bottom left, check it for any loose cable, disconnected cable, or visible damage.
![]() | ![]() |
Re-calibrate the loadcell
Navigate to LCD Menu - Control - Calibration and test - Loadcell test to restart the loadcell calibration.
During the test, you will be asked to tap the nozzle at a specific time, and a progress bar on top of the screen will be filled. If the progress bar is not filled or the printer shows any errors, please contact our customer support.