The Prusa CORE One, and the Original Prusa MK4/S, MK3.9/S are equipped with a loadcell, which detects whether the nozzle is close enough to the steel sheet for printing and prevents damage from the nozzle digging into the steel sheet.
During a selftest, the loadcell is tested. The loadcell can also be tested at any time through the printer menu. If the loadcell calibration is not done, or the printer does not recognize that it has been done, it will show the message: "Loadcell calibration is not finished. Finish the calibration first."
Error name: Loadcell Not Calibrated
Error code: #31523 (CORE One) #26523 (MK4S) #13523 (MK4) #27523 (MK3.9S) #21523 (MK3.9)
Access the right side of the LoveBoard, where the loadcell cable is connected. To remove the side LoveBoard cover, on CORE One loosen two M3x6 bolts, on MK4/S and MK3.9/S loosen one M3x10 bolt.
Once accessed, locate the loadcell connector and cable, and check for any loose cable, disconnected cable, or visible damage.
Navigate to LCD Menu -> Control -> Calibrations & Tests -> Loadcell Test to initiate a loadcell test.
During the test, you will be asked to tap the nozzle at a specific time, and a progress bar shown on the screen is filled, depending on the pressure applied to the loadcell. If the bar is not filled or is filled irregularly, please contact our customer support.